10% off online bookings!
2006 GE OEC 9900 Elite ESP
Summary
The GE OEC 9900 Elite C-arm offers improved image quality and monitoring. The 9900 Elite can perform DSA (Digital Subtraction Angiography) while either moving the c-arm or the patient. The c-arm has an easy-to-use interface and a deeper arch to allow for better access to the patient for specific procedures like cardiovascular and pain management. The GE system applies algorithms and a variety of different bandwidths that are preprogrammed - this can provide improved accuracy and definition to the images. The GE 9900 Elite comes with a dual flat panel and touchscreen monitor. This makes it easier to maneuver the monitor to comfortably view the c-arm images from any angle.
-
1k2 High Resolution Imaging Chain
-
Dynamic Range Management (DRM)
-
Tri-Mode 9 or 12 Inch Image Intensifier
-
Digital Imaging Rotation
-
1k x 1k CCD Camera
-
Full Frame Capture AutoTrak
-
Automatic Brightness Stabilization
-
Bolus Chase Preset - 30 Pulse/second
-
Recording Playback up to 30 FPS
-
Dual 18-Inch Anti-Glare Touch Flat Panel Displays on an Articulating Arm
-
15kW power generator – 60kHz high frequency- Up to 120Vp
-
Rotating anode X-ray tube
-
Digital Image Rotation
-
Fluoro Mode
-
Pulsed Fluoro Mode
-
High Level Pulsed Fluoro
-
Digital Spot Mode
-
Radiographic Mode
-
Easy archiving and documentation
-
Physician controlled x-ray footswitch and handswitch
-
High-Power pulse anode
-
Dynamic studies at up to 30 pps without motion artifact
-
Dicom 3.0 – Print
GE OEC 9900 Elite C-Arm Specifications:
X-ray System
-
60kHz high frequency
-
15kW power
-
Up to 120kVp
-
Up to 75mA for radiographic film exposure
-
Continuous high-level fluoro (HLF) up to 20mA
-
Digital spot up to 75mA
-
Digital cine pulse
-
15 or 30 pulses per second, 60 Hz
-
12 or 25 pulses per second, 50 Hz
-
Up to 150mA
-
10ms pulse width
-
-
Full power from standard wall outlet
-
Patented battery buffered design
X-ray Tube
-
Rotating anode X-ray
-
tube0.3 and 0.6 nominal focal spots
-
Anode heat capacity: 300,000 HU
-
Anode cooling rate: 85,000 HU/min.
-
Housing heat capacity: 1,600,000 HU
-
Housing cooling rate:
-
9” I.I. Super C- 22,500 HU/min
-
12” I.I. - 22,500 HU/min
-
Digital Image Rotation
-
Digitally adjusts image display
-
Automatic image update
-
Image rotation
-
Image reversal (side-to-side)
-
Image invert (top-to-bottom)
-
-
Image positioning without additional exposure
Preview Collimator
-
On-screen collimator position indication
-
PreView iris collimator
-
PreView Tungsten rotatable double leaf collimator
-
Adjusts collimators without X-ray exposure
Fluoro Mode
-
kVp range: 40 -120
-
mA range:
-
0.2 - 10 normal mode
-
1.0 - 20 HLF (high level fluoro)
-
-
Auto and manual fluoro modes
-
AutoTrak ABS varies mA, kVp, camera gain
Pulsed Fluoro Mode
-
kVp range: 40 - 120
-
mA range: 0.2 - 10
-
Pulse rate: 1, 2, 4, 8
-
Pulse width: 25 or 50ms
-
AutoTrak ABS, mA, kVp, camera gain
-
Reduces X-ray dose to patient and operator
High Level Pulsed Fluoro
-
kVp range: 40 - 120
-
mA range: 1 - 40
-
Pulse rate: 1, 2, 4, 8
-
Pulse width: 25 or 50ms
-
AutoTrak ABS, mA, kVp, and camera gain
Digital Spot Mode
-
kVp range: 40 - 120
-
mA range: Up to 75
-
Automatic exposure termination and automatic image save
Radiographic Mode
-
mA range: up to 75
-
mAs range: up to 300
-
Computer controlled exposure time
-
Optional film cassette holder
-
10” x 12” (24cm x 30cm) for 9” I.I.
-
14” x 14” (35cm x 35cm) for 12” I.I.
-
Video Imaging System
9" Image Intensifier
-
Tri-mode 9”/6”/4.5” (23cm/15cm/11cm) image intensifier
-
Minimum central resolution (at monitor):
-
9” (23cm): 2.2 lp/mm
-
6” (15cm): 3.0 lp/mm
-
4.5” (11cm): 3.5 lp/mm
-
-
DQE: 65% (typical)
12" Image Intensifier
-
Tri-mode 12”/9”/6” (31cm/23cm/15cm) image intensifier
-
Minimum central resolution (at monitor):
-
12” (23cm): 1.6 lp/mm
-
9” (15cm): 2.2 lp/mm
-
6” (11cm): 2.6 lp/mm
-
-
DQE: 65% (typical)
Precision Imaging with Dynamic Range Management (DRM)
-
Preset Imaging Profile: Orthopedic
-
Enhances features of interest while attenuating background noise
AutoTrak Automatic Brightness Stabilization (ABS)
-
Automatically seeks the subject anatomy anywhere within the imaging field and selects the optimum imaging technique
-
Automatically adjusts to anatomical size and location
-
Provides uniform image quality throughout the entire image
-
Simplifies operation
Image Quality Features
-
Smart Window
-
Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality
-
-
Smart Metal
-
Allows the user to adjust automatic brightness and contrast sensitivity levels to metal
-
Provides optimum image quality even when metal is introduced to the field
-
-
Tungsten Collimator
-
Dense collimator limits X-ray exposure area
-
Reduces scatter radiation
-
Improves image detail
-
Video Camera
-
High resolution 1k x 1k CCD camera
-
Full frame capture
-
Motorized rotation
-
On-screen orientation indicator (real-time feedback without fluoro)
-
Left-right image reversal
-
Top-bottom image invert
Video Display
-
Dual 19” (48cm) display anti-glare, LCD flat panel monitors mounted on an articulating arm
-
22” horizontal travel
-
7° up/10° down
-
Monitors viewable from all four sides of workstation
-
Horizontal and vertical viewing angle 170°
-
-
1200 CD/M2 maximum brightness
-
Touch screen system control
-
1280 x 1024 high resolution monitors
-
Integrated color monitor for display of VGA, DVI, DVI-D, S-VHS, and SDISD formats
Location
Lakewood, Ohio
Year
2006
Cost
$57,577